Do you have to be qualified to test emergency lighting?

Author

Michael Henderson

Published Feb 17, 2026

Do you have to be qualified to test emergency lighting?

Annually – A full system inspection and duration test of the emergency lights should be performed by a ‘competent person’, this being a person with the necessary skills, training and knowledge to perform emergency lighting maintenance and servicing.

What is an emergency lighting completion certificate?

The completed certificate is intended to confirm that the emergency lighting installation, detailed in. Section B of the certificate has been fully inspected and tested and, except for the deviations (if any) recorded in Section I of the certificate, complies with the requirements of BS 7671: 2008 – Requirements.

How long does an emergency lighting certificate last?

It is really important that emergency lights are given a full rated duration test every year. That means if the emergency lights back up should provide 3 hours of illumination (which is often the case), they need to be tested for the full 3 hours to ensure they’re still working at the end of the test.

Can I test my own emergency lighting?

Self-testing emergency lights check themselves automatically to ensure that the battery and lamp in each emergency light are fully operational. The self-test feature replaces the manual tests carried out monthly and annually.

What are the legal requirements for emergency lighting?

Article 14 of the regulations states that: “Emergency routes and exits must be indicated by signs; and emergency routes and exits requiring illumination must be provided with emergency lighting of adequate intensity in the case of failure of their normal lighting.”

What is a 3 hour emergency light test?

What is a 3 hour emergency light test? The minimum permitted duration of an emergency escape lighting system is 1 hour and so your annual emergency lighting test will check that all of your lights turn on and stay on for at least 60 minutes and for as long as 3 hours, depending on the type of batteries you are using.

How often should emergency lights be tested?

All emergency lighting systems should be tested monthly. This is a short functional test in accordance with BS EN 50172:2004 / BS 5266-8:2004. The duration of the test should be sufficient to ensure that the luminaire operates correctly, whilst minimising any damage to the system components, e.g. Lamps, Battery.

Does HMO need emergency lighting?

The legislation would be the RRO – typically, Emergency/escape lighting is not required in 1 and 2 storey HMOs, Except: If the route of escape is complex or lengthy or; The HMO is occupied by 6 or more persons or; Where no natural light is available.

How do you test for maintained emergency lighting?

To test the emergency light. Put the test key into the key switch and just like a light switch click it into test mode. This will simulate the power being cut to the emergency light. You should check that all the emergency lights in that area have come on.

Do emergency lights need a test switch?

Emergency lighting key switches are available and allow for the interruption of the power to the emergency lights without affecting the power supply to the normal lighting circuits. A test for the full duration (usually three hours) of the emergency lights must be carried out once a year.

How do you do a 90 minute emergency light test?

In brief, the 90-minute battery load test is when you bring in an outside party to test your emergency and exit lights for a duration of 90 minutes. They will shut off the power to the lights to mimic power loss in an emergency situation and require the lights to switch to battery-power.

How much is an emergency lighting test?

Emergency Lighting Testing starts from £95.00 +VAT. This is for up to 10 luminaires and includes the above. Additional savings may apply when Emergency Lighting Testing is booked together with PAT Testing and/or EICR. Note – Special rates apply for out of hours and weekend appointments.

What is the addressable monitoring system of emergency lighting?

The addressable monitoring system of emergency lighting is appropriate for big installations, such as hospitals, malls, hotels, industries, universities, schools, airports, metro and railway stations due to the capability of central monitoring of the installation and the easy and quick maintenance of the system.

What are addressable emergency luminaries?

Τhe addressable, self contained emergency luminaries are power supplied by mains and connected with addressable monitoring panel via shielded, twisted pair cable in order to transfer the appropriate data to the panel. The communication protocol of the system is Olympia Protocol and is developed exclusively for this system.

What is an emergency lights system?

The emergency lights system shall include Static Inverter Central Battery (SICB) systems feeding emergency Lighting luminaries to achieve a backup period of at least 3 hours. This system shall also be backed up by the standby generators for additional redundancy in case of long power failures.

What is the emergency lighting system power cabling requirement?

The emergency lighting system power cabling has to be mandatory Meggered and Continuity checked and rectified of all Open/Short/Earth Faults prior to commencement of connection and powering up of the circuits.